101401-1665 ZEXEL 9 400 611 571 BOSCH INJECTION-PUMP ASSEMBLY 9400611571 1014011665 me017619


101401-1665 INJECTION-PUMP ASSEMBLY
Rating:
30
Buy INJECTION-PUMP ASSEMBLY 101401-1665 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 611 571 9400611571
ZEXEL 101401-1665 1014011665
MITSUBISHI ME017619 me017619

Service parts 101401-1665 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-9890
3. GOVERNOR 105921-6795
4. SUPPLY PUMP 105220-6050
5. AUTOM. ADVANCE MECHANIS 105676-0811
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5761
11. Nozzle and Holder ME016992
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105048-3501
14. NOZZLE 105017-2240
15. NOZZLE SET

Include in #1:

101401-1665 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 611 571 9400611571
ZEXEL 101401-1665 1014011665
MITSUBISHI ME017619 me017619


Zexel num
Bosch num
Firm num
Name
101401-1665 
9 400 611 571 
ME017619  MITSUBISHI
INJECTION-PUMP ASSEMBLY
4D34T4 K 14BD INJECTION PUMP ASSY PE4AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8820
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.6
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   71.5 69.9 73.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   365 365 365
Average injection quantity mm3/st.   19.5 18.2 20.8
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.6)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   71.5 70.5 72.5
Basic   *
Fixing the lever   *
Boost pressure kPa   22 22
Boost pressure mmHg   165 165
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+1.8
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   92 88 96
Fixing the lever   *
Boost pressure kPa   22 22
Boost pressure mmHg   165 165
Injection quantity adjustment_05
Adjusting point   C
Rack position   (R1-1)
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   45 41 49
Fixing the lever   *
Boost pressure kPa   22 22
Boost pressure mmHg   165 165
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2-0.35
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   25.3 21.3 29.3
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   300 300 300
Rack position   R2-0.35
Boost pressure kPa   4 2.7 5.3
Boost pressure mmHg   30 20 40
Boost compensator adjustment_02
Pump speed r/min   300 300 300
Rack position   R2(R1-0. 65)
Boost pressure kPa   8.7 8.7 8.7
Boost pressure mmHg   65 65 65
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   4.5 4 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-1665
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=J33 BCL=0.35+-0.1mm
----------

Speed control lever angle

Test data 101401-1665
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101401-1665
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=40mm
----------
a=33deg+-5deg b=40deg+-5deg

Timing setting

Test data 101401-1665
(1)Pump vertical direction (2)Position of gear mark '3' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(130deg)




Have questions with 101401-1665?





Group cross 101401-1665 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME017285 
INJECTION-PUMP ASSEMBLY
4D34T4
101401-1665  
9 400 611 571 
ME017619 
INJECTION-PUMP ASSEMBLY
4D34T4
Back to top