101401-1660 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014011660


101401-1660 INJECTION-PUMP ASSEMBLY
Rating:
25
Buy INJECTION-PUMP ASSEMBLY 101401-1660 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-1660 1014011660

Cross reference number

ZEXEL 101401-1660 1014011660


Zexel num
Bosch num
Firm num
Name
101401-1660 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8820
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.9
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   73.9 72.3 75.5
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   11.2 9.9 12.5
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.9)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   73.9 72.9 74.9
Basic   *
Fixing the lever   *
Boost pressure kPa   24.7 24.7
Boost pressure mmHg   185 185
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+1.9
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   94.8 90.8 98.8
Fixing the lever   *
Boost pressure kPa   24.7 24.7
Boost pressure mmHg   185 185
Injection quantity adjustment_05
Adjusting point   C
Rack position   (R1-1)
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   46.3 42.3 50.3
Fixing the lever   *
Boost pressure kPa   24.7 24.7
Boost pressure mmHg   185 185
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2-0.65
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   18.7 14.7 22.7
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   300 300 300
Rack position   R2-0.65
Boost pressure kPa   4 2.7 5.3
Boost pressure mmHg   30 20 40
Boost compensator adjustment_02
Pump speed r/min   300 300 300
Rack position   R2(R1-0. 65)
Boost pressure kPa   11.3 11.3 11.3
Boost pressure mmHg   85 85 85
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   4.5 4 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-1660
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=H62 BCL=0.65+-0.1mm
----------

Speed control lever angle

Test data 101401-1660
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101401-1660
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=40mm
----------
a=33deg+-5deg b=40deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=1025r/min Ra=8.5+-0.1mm
----------

Timing setting

Test data 101401-1660
(1)Pump vertical direction (2)Position of gear mark '3' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(130deg)




Have questions with 101401-1660?





Group cross 101401-1660 ZEXEL

101401-1660  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME017285 
INJECTION-PUMP ASSEMBLY
4D34T4
9 400 611 571 
ME017619 
INJECTION-PUMP ASSEMBLY
4D34T4