101401-0772 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014010772 8944551021


101401-0772 INJECTION-PUMP ASSEMBLY
Rating:
50
Buy INJECTION-PUMP ASSEMBLY 101401-0772 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-0772 1014010772
ISUZU 8944551021 8944551021

Cross reference number

ZEXEL 101401-0772 1014010772
ISUZU 8944551021 8944551021


Zexel num
Bosch num
Firm num
Name
101401-0772 
101401-0773 
 
8944551021  ISUZU
INJECTION-PUMP ASSEMBLY
4BD1T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.6
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.1 70.5 73.7
Max. variation between cylinders %   0 -4 4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   12.1 10.8 13.4
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.6)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.1 71.1 73.1
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.2
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   82.6 79.4 85.8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.1
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   53.6 49.6 57.6
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   (R1+0.1)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   76.1 72.9 79.3
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   116 116 124
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1000+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1600
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-0772
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=C52
----------

Speed control lever angle

Test data 101401-0772
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=3.5deg+-5deg b=27deg+-3deg

Stop lever angle

Test data 101401-0772
N:Pump normal S:Stop the pump.
----------

----------
a=45deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101401-0772
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(11.6)mm Rb=(R1-0.15)mm Pa=79.4+-2.7kPa(596+-20mmHg) Pb=70.1+0.7kPa(526+-5mmHg) Q1=72.1+-1cm3/1000st Q2=69.8+-1.6cm3/1000st

Timing setting

Test data 101401-0772
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=13deg
----------
a=(100deg)




Have questions with 101401-0772?





Group cross 101401-0772 ZEXEL

Isuzu 

 
8944471892 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944471893 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944471894 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944471895 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944471896 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944471897 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 573 
8944471899 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 412 
8971385980 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 574 
8944503731 
INJECTION-PUMP ASSEMBLY
4BB1
 
8944529650 
INJECTION-PUMP ASSEMBLY
4BB1
 
8944556960 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944556961 
INJECTION-PUMP ASSEMBLY
4BD12
9 400 613 575 
8944556962 
INJECTION-PUMP ASSEMBLY
9 400 613 575 
8944556963 
INJECTION-PUMP ASSEMBLY
 
8944556970 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944556971 
INJECTION-PUMP ASSEMBLY
4BD12
9 400 613 576 
8944556972 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944551020 
INJECTION-PUMP ASSEMBLY
4BD1T
 
 
INJECTION-PUMP ASSEMBLY
4BD1T
101401-0772  

101401-0773 
 
8944551021 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 349 
8944551023 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8944637891 
INJECTION-PUMP ASSEMBLY
4BD12
 
8944637892 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944574770 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8944574771 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 610 390 
8944574773 
INJECTION-PUMP ASSEMBLY
4BD1T
Back to top