101401-0610 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014010610


101401-0610 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 101401-0610 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-0610 1014010610

Cross reference number

ZEXEL 101401-0610 1014010610


Zexel num
Bosch num
Firm num
Name
101401-0610 
101401-0612 
 
  ISUZU
INJECTION-PUMP ASSEMBLY
4BD1T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.3
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   74.5 72.9 76.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.6+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.3)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   74.5 73.5 75.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   I
Rack position   14.4+-0. 5
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   79 79 87
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1000+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1600
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-0610
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B19
----------

Speed control lever angle

Test data 101401-0610
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=2.5deg+-5deg b=32deg+-3deg

Stop lever angle

Test data 101401-0610
N:Pump normal S:Stop the pump.
----------

----------
a=45deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101401-0610
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(12.3)mm Rb=(R1-0.3)mm Pa=89.8+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=74.5+-1cm3/1000st Q2=71+-1.5cm3/1000st

Timing setting

Test data 101401-0610
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(100deg)




Have questions with 101401-0610?





Group cross 101401-0610 ZEXEL

Isuzu 

 
8941788200 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 567 
8941788201 
INJECTION-PUMP ASSEMBLY
4BD1
101401-0610  

101401-0612 
 
 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941778740 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941778741 
INJECTION-PUMP ASSEMBLY
4BD1T
 
 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941778750 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941778751 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941778730 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 568 
8941778731 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944077400 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 569 
8944077402 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944111640 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944081972 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 570 
8944081973 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 571 
8944207480 
INJECTION-PUMP ASSEMBLY
4BD1
 
8944122910 
INJECTION-PUMP ASSEMBLY
4BB1
 
8944020560 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8944020561 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 572 
8944020562 
INJECTION-PUMP ASSEMBLY
4BD1T
Back to top