101401-0551 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014010551 8941573532


101401-0551 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 101401-0551 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-0551 1014010551
ISUZU 8941573532 8941573532

Cross reference number

ZEXEL 101401-0551 1014010551
ISUZU 8941573532 8941573532


Zexel num
Bosch num
Firm num
Name
101401-0551 
101401-0552 
 
8941573532  ISUZU
INJECTION-PUMP ASSEMBLY
4BD1T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.8
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.6 71 74.2
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   11.4 10.1 12.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.8)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.6 71.6 73.6
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.05
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   80.1 76.9 83.3
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.05
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   56 52.8 59.2
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   116.5 116.5 124.5
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1150+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1500
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-0551
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B38
----------

Speed control lever angle

Test data 101401-0551
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=2.5deg+-5deg b=34deg+-3deg

Stop lever angle

Test data 101401-0551
N:Pump normal S:Stop the pump.
----------

----------
a=45deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101401-0551
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(11.8)mm Rb=(R1-0.3)mm Pa=89.8+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=72.6+-1cm3/1000st Q2=67+-1.5cm3/1000st

Timing setting

Test data 101401-0551
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=6deg
----------
a=(100deg)




Have questions with 101401-0551?





Group cross 101401-0551 ZEXEL

Isuzu 

 
8941606660 
INJECTION-PUMP ASSEMBLY
4BD1-T
 
8941606662 
INJECTION-PUMP ASSEMBLY
4BD1-T
 
8941606663 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 558 
8941606664 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941676771 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 559 
8941676772 
INJECTION-PUMP ASSEMBLY
4BD1
 
 
INJECTION-PUMP ASSEMBLY
4BD1-T
 
8941699182 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 560 
8941699183 
INJECTION-PUMP ASSEMBLY
4BD1T
 
 
INJECTION-PUMP ASSEMBLY
4BD1-T
 
8941699192 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 561 
8941699193 
INJECTION-PUMP ASSEMBLY
4BD1T
 
 
INJECTION-PUMP ASSEMBLY
4BD1-T
 
8941573522 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 562 
8941573523 
INJECTION-PUMP ASSEMBLY
4BD1T
 
 
INJECTION-PUMP ASSEMBLY
4BD1-T
101401-0551  

101401-0552 
 
8941573532 
INJECTION-PUMP ASSEMBLY
4BD1T
9 400 613 563 
8941573533 
INJECTION-PUMP ASSEMBLY
4BD1T
 
8941573502 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 564 
8941573503 
INJECTION-PUMP ASSEMBLY
4BD1
 
8941573512 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 565 
8941573513 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 613 566 
8941735890 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 610 049 
8941787190 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 619 519 
8941787191 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 610 389 
8941787192 
INJECTION-PUMP ASSEMBLY
4BD1
Back to top