Rating:
Information injection-pump assembly
ZEXEL
104748-2200
1047482200
Cross reference number
ZEXEL
104748-2200
1047482200
Zexel num
Bosch num
Firm num
Name
104748-2200
NISSAN
INJECTION-PUMP ASSEMBLY
CD17 *
CD17 *
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
(Solenoid timer adjustment condition)
OFF OFF
OFF OFF
Injection timing adjustment
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.6
29.6
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.4
18.4
Injection timing adjustment_03
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
27.7
25.7
29.7
Injection timing adjustment_04
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.1
30.1
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
26.3
24.3
28.3
Injection quantity adjustment
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.9
17.9
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2900
2900
2900
Average injection quantity
mm3/st.
6
Governor adjustment
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
6.8
5.3
8.3
Difference in delivery
mm3/st.
3
Basic
*
Governor adjustment_02
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
6.8
4.8
8.8
Governor adjustment_03
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
3
Boost compensator adjustment
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
15
10
20
Lever angle (shim thickness)
mm
8.9
8.6
9.2
Remarks
From idle
From idle
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50.3
45.3
55.3
Basic
*
Speed control lever angle
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1200
1200
1200
Overflow quantity with S/T OFF
cm3/min
348
216
480
Stop lever angle
Pump speed
r/min
1200
1200
1200
Pressure with S/T OFF
kPa
333.5
304
363
Pressure with S/T OFF
kgf/cm2
3.4
3.1
3.7
Basic
*
Remarks
OFF
OFF
Stop lever angle_02
Pump speed
r/min
1200
1200
1200
Pressure with S/T OFF
kPa
333.5
294
373
Pressure with S/T OFF
kgf/cm2
3.4
3
3.8
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Pressure with S/T OFF
kPa
461
422
500
Pressure with S/T OFF
kgf/cm2
4.7
4.3
5.1
Stop lever angle_04
Pump speed
r/min
2500
2500
2500
Pressure with S/T OFF
kPa
618
579
657
Pressure with S/T OFF
kgf/cm2
6.3
5.9
6.7
0000001101
Pump speed
r/min
1200
1200
1200
Timer stroke with S/T OFF
mm
2.6
2.3
2.9
Basic
*
Remarks
OFF
OFF
_02
Pump speed
r/min
800
800
800
Timer stroke with S/T OFF
mm
1.1
0.5
1.7
_03
Pump speed
r/min
1200
1200
1200
Timer stroke with S/T ON
mm
3.2
2.8
3.6
Timer stroke with S/T OFF
mm
2.6
2.2
3
_04
Pump speed
r/min
2500
2500
2500
Timer stroke with S/T OFF
mm
7.95
7.4
8.5
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001501
Pump speed
r/min
1200
1200
1200
Atmospheric pressure difference
kPa
-18.7
-19.4
-18
Atmospheric pressure difference
mmHg
-140
-145
-135
Decrease qty
mm3/st.
2.6
1.1
4.1
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.6
1.5
1.7
Control lever angle alpha
deg.
24
20
28
Control lever angle beta
deg.
44
39
49
Control lever angle gamma
deg.
14
13.5
14.5
Test data Ex:
0000001501 ANEROID COMPENSATOR
ACS adjustment
Full load injection quantity at high altitudes and ACS adjusting method
1. Full load injection quantity adjustment
(1)Remove the ACS cover and remove the bellows and adjusting shim.
(2)Perform all adjustments as per the adjustment standard except for ACS adjustment.
2. ACS adjustment
(1)Assemble the ACS cover, bellows and adjusting shim.
(2)At N = N1, adjust using shims so that the decrease amount for altitude is as specified in the graph.
N:Pump speed
X1:Atmospheric pressure
X2:Altitude
Y:Decrease quantity
A:Adjustment value
B:Inspection value
----------
N1=1200r/min
----------
----------
N1=1200r/min
----------
0000001801 POTENTIOMETER ADJUSTMENT
Adjustment of the potentiometer
At pump speed N1 and oil temperature t, and at lever angle a (L1) from idle, adjust the potentiometer so that the specifications are satisfied.
Standard value : V+-0.03=0.187Q+1.593
Q = injection quantity
----------
N1=700r/min t=48~52degC a=14deg L1=8.9mm
----------
----------
N1=700r/min t=48~52degC a=14deg L1=8.9mm
----------
0000001901 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Adjustment of the advance angle of the timer
(1)Determine the timer advance angle using the graph.
Graph TA-t: -10<= t(deg C) <= 20 TA = -0.0284t+1.367
20 <= t (deg C) <= 60: TA = -0.02 t + 1.2
Graph L-t: 10 <= t (deg C) <= 20 L = -0.0667t+3.23
20 <= t (deg C) <= 60: L = -0.05 t + 2.9
(2)(1) Adjust with the screw (A) so that the timer advance angle determined in the item (1) is obtained.
2. Setting the intermediate lever position
(1)Insert a block gauge L1 between the idling set screw (G) and the control lever (F).
(2)Align the intermediate lever (D) with the aligning line (I) and position it perpendicularly. Fix screw (E) so that it contacts the control lever (F).
3. W-CSD lever adjustment
(1)Insert a block gauge L2 determined from the graph L - t in 1. (1) between the idle set screw (G) and the control lever (F).
(2)Fix screw (B) so that the W-CSD lever (C)'s roller contacts the intermediate lever (D).
Note:
The temperature of the wax at adjustment must not exceed a.
When inserting the block gauge, separate lever (C) and (D) using screw (B) to prevent excessive force on the lever.
X:Temperature t (deg C)
Y1:Timer lift TA (mm)
Y2:Control lever L dimension [mm; control lever position (deg)]
(U) Perpendicular position
K:Water temperature
M:Starting timer stroke
N:Fast idle lever position
O:Standard point
----------
L1=1.0+-0.05mm L2=L+-0.05mm a=30degC
----------
L1=1.0+-0.05mm K1=70+-0.5degC K2=20+-0.5degC K3=-10+-0.5degC M1=0mm M2=0.8+-0.2mm M3=1.65mm N1=0deg N2=3+-0.5deg N3=6.1deg N4=0mm N5=1.9+-0.3mm N6=3.9mm
----------
L1=1.0+-0.05mm L2=L+-0.05mm a=30degC
----------
L1=1.0+-0.05mm K1=70+-0.5degC K2=20+-0.5degC K3=-10+-0.5degC M1=0mm M2=0.8+-0.2mm M3=1.65mm N1=0deg N2=3+-0.5deg N3=6.1deg N4=0mm N5=1.9+-0.3mm N6=3.9mm
Have questions with 104748-2200?
Group cross 104748-2200 ZEXEL
Nissan
104748-2200
INJECTION-PUMP ASSEMBLY
CD17
CD17