Rating:
Information injection-pump assembly
ZEXEL
104742-1060
1047421060
ISUZU
8944626460
8944626460
Cross reference number
ZEXEL
104742-1060
1047421060
ISUZU
8944626460
8944626460
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
(Solenoid timer adjustment condition)
OFF
Injection timing adjustment
Pump speed
r/min
1050
1050
1050
Average injection quantity
mm3/st.
62.3
61.8
62.8
Difference in delivery
mm3/st.
4
Basic
*
Remarks
OFF
OFF
Injection timing adjustment_02
Pump speed
r/min
2100
2100
2100
Average injection quantity
mm3/st.
13.5
10
17
Remarks
OFF
OFF
Injection timing adjustment_03
Pump speed
r/min
1750
1750
1750
Average injection quantity
mm3/st.
62.4
56.9
67.9
Remarks
OFF
OFF
Injection timing adjustment_04
Pump speed
r/min
1400
1400
1400
Average injection quantity
mm3/st.
59.3
55.3
63.3
Remarks
OFF
OFF
Injection timing adjustment_05
Pump speed
r/min
1050
1050
1050
Average injection quantity
mm3/st.
62.3
61.3
63.3
Remarks
OFF
OFF
Injection timing adjustment_06
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
50.7
46.7
54.7
Remarks
OFF
OFF
Injection timing adjustment_07
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
47
42.5
51.5
Remarks
OFF
OFF
Injection quantity adjustment
Pump speed
r/min
2100
2100
2100
Average injection quantity
mm3/st.
13.5
10.5
16.5
Difference in delivery
mm3/st.
7
Basic
*
Remarks
OFF
OFF
Injection quantity adjustment_02
Pump speed
r/min
2200
2200
2200
Average injection quantity
mm3/st.
8
Remarks
OFF
OFF
Governor adjustment
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
9.4
7.4
11.4
Difference in delivery
mm3/st.
2
Basic
*
Remarks
OFF
OFF
Governor adjustment_02
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
9.4
7.4
11.4
Remarks
OFF
OFF
Governor adjustment_03
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
3
Remarks
OFF
OFF
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
80
80
Basic
*
Remarks
OFF
OFF
Speed control lever angle
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1600
1600
1600
Overflow quantity with S/T OFF
cm3/min
620
490
750
Stop lever angle
Pump speed
r/min
1600
1600
1600
Pressure
kPa
588.5
569
608
Pressure
kgf/cm2
6
5.8
6.2
Basic
*
Remarks
OFF
OFF
Stop lever angle_02
Pump speed
r/min
1000
1000
1000
Pressure with S/T OFF
kPa
343.5
314
373
Pressure with S/T OFF
kgf/cm2
3.5
3.2
3.8
Stop lever angle_03
Pump speed
r/min
1600
1600
1600
Pressure with S/T OFF
kPa
588.5
569
608
Pressure with S/T OFF
kgf/cm2
6
5.8
6.2
Stop lever angle_04
Pump speed
r/min
1750
1750
1750
Pressure with S/T OFF
kPa
637.5
608
667
Pressure with S/T OFF
kgf/cm2
6.5
6.2
6.8
0000001101
Pump speed
r/min
1600
1600
1600
Timer stroke
mm
3
2.8
3.2
Basic
*
Remarks
OFF
OFF
_02
Pump speed
r/min
750
650
850
Timer stroke with S/T ON
mm
0.5
0.5
0.5
_03
Pump speed
r/min
1450
1450
1450
Timer stroke with S/T OFF
mm
0.5
_04
Pump speed
r/min
1500
1500
1500
Timer stroke with S/T OFF
mm
0.9
0.3
1.5
_05
Pump speed
r/min
1600
1600
1600
Timer stroke with S/T OFF
mm
3
2.7
3.3
_06
Pump speed
r/min
1750
1750
1750
Timer stroke with S/T OFF
mm
5.7
5.3
6.1
0000001201
Max. applied voltage
V
16
16
16
Test voltage
V
25
24
26
Timing setting
K dimension
mm
3.1
3
3.2
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
0.9
0.8
1
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
Refer to additional devices. deg. 50 46 54
Refer to additional devices. deg. 50 46 54
Control lever angle beta
deg.
35
30
40
Test data Ex:
0000001801 TEMP. ADJUST FULL-LOAD SCREW
Temporary full load screw adjustment
Set the full load screw protrusion at L mm at assembly.
----------
L=14.0+-0.5mm
----------
L=14.0+-0.5mm
----------
L=14.0+-0.5mm
----------
L=14.0+-0.5mm
0000001901 CONTROL LEVER ANGLE
Lever angle alpha, beta
Dimensions a, b
----------
Alpha=50+-4degC Beta=35+-5degC a=(4.8~7.6)mm b=(11.1~15.6)mm
----------
Alpha=50+-4degC Beta=35+-5degC a=(4.8~7.6)mm b=(11.1~15.6)mm
----------
Alpha=50+-4degC Beta=35+-5degC a=(4.8~7.6)mm b=(11.1~15.6)mm
----------
Alpha=50+-4degC Beta=35+-5degC a=(4.8~7.6)mm b=(11.1~15.6)mm